Please note: Our distribution rights for the Luminex Calibration and Control Microspheres were terminated on December 31st, 2011. We recommend you contact the manufacturer, Luminex Corporation at luminexcorp.com to acquire these products. We apologize for any inconvenience this may cause and we look forward to serving you in the future.

Hitachi Solutions America, Ltd. continues to offer market leading analysis software for data generated by the LX100/200, Bio-Plex 100/200, FlexMAP 3D and MAGPIX instruments. To learn more about our software follow the links below:

MasterPlex QT – absolute quantitative analysis (unknown concentration calculation) and IC50 calculations
MasterPlex EX – relative quantitative analysis (gene expression)
MasterPlex GT – qualitative analysis (genotyping, SNP analysis etc.)

Luminex Calibration and Control Microspheres Luminex Calibration and Control Microspheres

The powerful multiplexing capabilities of the Luminex systems and software are due to advanced chemistry and simplicity of the Luminex® Coupling Beads.

Hitachi Software is a globally licensed distributor of xMAP instruments and reagents. Our xMAP products are manufactured and shipped directly by Luminex Corporation.

5 mL xMAP® Classification Calibration Microspheres

Microspheres of known fluorescent light intensities used to calibrate the settings for both classification channels and the doublet discrimination channel for the Luminex 200 and the Luminex 100 IS systems.

Concentration 4.0 x 105 microspheres/mL
Size 5.6 microns
Material Polystyrene
Shelf life 2 years after date of manufacture
Storage Store in sealed container in cool (2-8°C), dry location and away from oxidizers.

5mL xMAP® Reporter Calibration Microspheres

Microspheres of known fluorescent light intensities used to calibrate the settings for the reporter channel for the Luminex 200 and the Luminex 100 IS systems.

Concentration 4.0 x 105 microspheres/mL
Size 5.6 microns
Material Polystyrene
Shelf life 2 years after date of manufacture
Storage Store in sealed container in cool (2-8°C), dry location and away from oxidizers.

5 ml xMAP® Classification Control Microspheres

Microspheres that are used to verify the calibration and optical integrity for both the classification channels and doublet discrimination channel for the Luminex system.

Concentration 5.5 x 105 microspheres/mL
Size 5.6 microns
Material Polystyrene
Shelf life 2 years after date of manufacture
Storage Store in sealed container in cool (2-8°C), dry location and away from oxidizers.

5 ml xMAP® Reporter Control Microspheres

Microspheres that are used to verify the calibration and optical integrity for the reporter channel for the Luminex system.

Concentration 4.4 x 105 microspheres/mL
Size 5.6 microns
Material Polystyrene
Shelf life 2 years after date of manufacture
Storage Store in sealed container in cool (2-8°C), dry location and away from oxidizers.